New Agilent InfinityLab Poroshell 120 1.9 μm columns

New Agilent InfinityLab Poroshell 120 1.9 μm columns provide a unique combination of high efficiency, manageable pressure, and long lifetime.

  • Ultra-fast separations increase productivity and decrease your cost per sample
  • Increase resolution and accuracy and reduce re-work by combining manageable pressure with longer, high efficiency InfinityLab Poroshell 120 1.9 μm colums
  • Rugged performance: InfinityLag Poroshell 120 1.9 μm columns remain stable for 5000 injections under high-pressure UHPLC conditions.
Poroshell 120

InfinityLab Poroshell 120 columns are based on superficially porous particle technology, which features a solid silica core and a porous outer layer. Compared to traditional totally porous particles of the same (or similar) size, InfinityLab Poroshell particles deliver higher chromatographic efficiencies and enable fast, high-resolution separations.

Solid Core Porous Layer Particle size Pressure Limit
1.2 μm 0.35 μm 1.9 μm 1300 bar

Use long-life and robust InfinityLab Poroshell 120 1.9 μm columns and chose the most suitable chemistry for your method:

Best use Aligned Chemistry Column family
Best all around EC-C18 Poroshell 120 Eclipse EC-C18
EC-C8 Poroshell 120 Eclipse EC-C8
Phenyl-Hexyl Poroshell 120 Phenyl-Hexyl
Best for high-pH mobile phases HPH-C18 Poroshell 120 HPH-C18
Best for alternative selectivity PFP
(Pentafluorophenyl)
Poroshell 120 PFP
Best for more polar compounds HILIC Poroshell 120 HILIC

Application Note – SpeedCore Method Transfer Document by Fortis Technologies

fortisHPLC

Fortis® Technologies Ltd. supplies UHPLC and HPLC columns to the pharmaceutical, environmental and foodstuffs industries. Their goal is to supply innovative solutions to the separation and purification industries.

In their new application note – Transfer of HPLC methods to SpeedCore particles – they outline how to transfer an old slow HPLC method to core-shell particles in order to provide a much faster method. Learn how to use 3 simple equations to change parameters to do this.

Method development kits from Fortis Technologies Ltd. can be obtained here:
Reversed Phase Selectivity Kit (C18 & Diphenyl)
Polar Selectivity Kit (H2o & DIOL)
SpeedCore Selectivity Kit (C18 & RP18-Amide)
SpeedCore Reversed Phase Kit (C18 & Diphenyl)

Heliflex™ and Econocap™ GC Columns still available

helifax

MEGA is the exclusive authorized licensee of the Heliflex™ and Econo-Cap™ GC columns and will continue to produce* the “ATTM -” and “ECTM -” GC columns (for example ATTM-624+ or ECTM-WAX+) in order to supply you with HeliflexTM and Econo-CapTM GC columns fully equivalent to those you’ve always used until now.
The GC columns are available at BGB Analytik. We will support you in your product-specific concerns and questions. Please contact us for more information or to place an order.


*:under W. R. Grace & Co.-Conn. (GRACE) and Alltech Associates, Inc. exclusive License
GRACE® is a trademark, registered in the United States and/or other countries, of W. R. Grace & Co.-Conn. ECONO-CAP™, HELIFLEX™, AT™ and EC™ are trademarks of Alltech Associates, Inc. MEGA® (Stylized) is a trademark, registered in the United States and/or other countries, of MEGA Capillary Columns Laboratory di Galli Stefano & C. s.n.c.

BGB HPLC Safety Products

Header_Safety_Products
The new BGB HPLC Safety Products offer maximum protection and operability for safe disposal of fluid waste and extraction systems of fluids without evaporation of hazardous substances. BGB HPLC Safety Products are compatible with the S.C.A.T.® product line, perfect in handling and easy to use.
Safety-Waste-Filter
Waste-Caps
Safety Air Inlet Valve
Safety-Caps
Safety-Funnel
Safety Accessories & Adapters
BGB offers 20% on BGB HPLC Safety Products valid until 31.12.2016. To benefit use promocode BG1611.
This promotion cannot be cumulated with other reductions or special tariffs.

T1 deactivated SGE Inlet Liners

Developed specifically for EPA Method 8270 – for determination of semi-volatile organic compounds in extracts prepared from many types of solid waste, soils, water samples, and air sampling media -Trajan’s TI deactivated liners are unique and application specific, extensively tested and optimized for semi-volatiles analysis.

SGE TI deactivated liner

Several compounds in Method 8270 are susceptible to excessive degradation in the GC flow path and are potentially difficult to analyse if the inlet liner is not properly deactivated. Trajan’s TI deactivated liners are tested using a mix containing low levels (2ng on column) of problematic compounds:
N-nitrosodimethylamine, aniline, 2,4-dinitrophenol, 4-nitrophenol, 2-methyl-4,6-dinitrophenol, 4-aminobiphenol, pentachlorophenol, benzidine, benzo(b)fluoranthene, benzo(k)fluoranthene, and 3,3′-dichlorobezidine

More information about Trajan’s TI deactivated liners is available here.

Deactivation of SGE TI Inlet Liners for EPA 8270 semi-volatiles analysis is certified using 2,4-dinitrophenol and pentachlorophenol to ensure response factors above EPA method requirements.

SGE TI Inlet Liners are now available for Agilent and Thermo 1300 series instruments.

Part Number SGE-09262019 – Agilent Inlet Liners Tapered with Quartz Wool pre-fitted o-ring and TI Deactivation 4 mm ID, Length 78.5 mm PK5
Part Number SGE-0926201901 – Agilent Inlet Liner Tapered with Quartz Wool pre-fitted o-ring and TI Deactivation 4 mm ID, Length 78.5 mm PK1

Agilent BioHPLC Seminar

Agilent AdvanceBio columns are designed to enhance the accuracy and speed of your biomolecule characterization, including monoclonal antibodies (mAbs), other proteins, peptides and synthetic oligonucleotides.

This seminar aims at giving the audience a brief insight in the advantages and use of Advance BioHPLC Performance products.

SPEAKERS

Mrs Katrien Sabbe, PhD in Chemistry. More than 15 years experience in chromatography in differents companies as VWR, Varian and now Agilent Technologies. Product Specialist columns and supplies for Benelux area.

Mr Francesco Spadola, PhD in Chemistry. Product Specialist columns and supplies for the complete south of Europe. Many years experience in both liquid chromatography (LC) and sample preparation.

The presentations are in French
Slides, questions and discussion in both French and English.
Entrance is free of charge

For registration please contact Cyril Poulard, BGB Analytik SA, Geneva.

AGENDA
Download as pdf

09:00 – 09:30 Arrival & registration – coffee
09:30 – 09:40 Welcome words
09:40 – 10:20 Characterizing MAbs: Typical analytical workflows and Agilent portfolio overview
10:20 – 11:10 Reversed Phase BioHPLC columns for Protein Identification and Impurity Profiling
11:10 – 11:30 Coffee break
11:30 – 12:15 Optimizing Quantification of mAb and ADC Aggregates with Agilent AdvanceBio SEC columns
12:15 – 13:45 Lunch
13:45 – 14:30 Overview of Agilent Glycan Mapping Solution
14:30 – 14:50 Coffee break
14:50 – 15:35 Ion Exchange Chromatography for charge variants analysis
15:35 – 15:45 Conclusion and closing comments

GoogleMaps View Location on Google Maps.

Introducing eVol®

eVol

eVol® is a digitally controlled positive displacement dispensing system that can be programmed to reproducibly and accurately perform a wide variety of liquid handling procedures. Everyone becomes an expert.

Key Benefits

  • The programmable digital drive means liquid handling procedures are user-independent, allowing more efficient workflow scheduling and a reduction in the re-analysis of incorrectly processed or false positive samples.
  • XCHANGE® analytical syringes can be easily and quickly changed allowing them to be dedicated to individual liquids, and methods, to prevent possible cross-contamination of reagents.

eVol will improve your laboratory workflow and reporting confidence in many ways.

Process Without eVol With eVol eVol Benefits
Standard Preparation Standards prepared in a large volume flask. From this standard aliquots are individually dispensed into autosampler vials. Standards are made up directly in the vial, including the make up solvent.
  • Less glassware usage
  • Reduces waste fluid
  • Significant time saving
  • Improved accuracy and reproducibility
  • Addition of Standards Small amounts of standard aspirated and dispensed into all samples before being transferred to an autosampler vial. One aspiration and a fast series of repeated accurate dispenses directly into vials.
  • Significant time saving
  • Improved accuracy and reproducibility
  • Delivery of derivatization agents Laboratory staff required to work in a fume hood with potentially hazardous materials, to prepare combinations of derivatization agents in open vials. Process completed with eVol® programmed to aspirate an amount of solvent or agent and then dispense aliquots into sealed vials. Single handed operation.
  • Improved operator safety, lower spill and splash risk
  • Ergonomic benefits behind fume hood screen
  • Improved accuracy and reproducibility
  • Less glassware use
  • Serial dilutions Transfer of a small amount of solution to another container. Solvent added to achieve the required volume. This is repeated multiple times to obtain the required final accurate concentration. One aspiration of the solution can be dispensed directly into the solvent to achieve the required accurate concentration.
  • Complete workflow simplification
  • Significant time savings
  • Improved accuracy
  • Less solvent required
  • Less glassware used
  • Only three eVol syringes are required to dispense liquid volumes covering the range from 200 nL to 1000 μL.

    eVol syringe changing chart

    View this video to learn about the benefits of using eVol, the world’s first digital analytical syringe. eVol improves the pace of laboratory processes while delivering improved accuracy and reproducibility, with standardized results independent of operator skill.

    Visit our shop for more information about eVol® accessories and supplies.

    New Raptor™ FluoroPhenyl Phase: Get the Power of HILIC and RP Modes in One LC Column

    • Capable of both reversed-phase and HILIC separations.
    • Ideal for increasing sensitivity and selectivity in LC-MS analyses.
    • Offers increased retention for charged bases.
    • Part of Restek’s Raptor™ LC column line featuring 2.7 and 5 μm SPP core-shell silica.
    • Increased retention and selectivity for basic and hydrophilic compounds compared to a C18.

    Switch to a Raptor™ FluoroPhenyl LC column for reliable performance in both reversed-phase and HILIC modes.

    Raptor™ FluoroPhenyl LC Columns Sales Sheet – Restek

    Read more about superficially porous particles here:

    Performance characteristics of new superficially porous particles (Journal of Chromatography A, Volume 1258, 5 October 2012, Pages 76–83, doi: 10.1016/j.chroma.2012.08.036)
    Applications of superficially porous particles: High speed, high efficiency or both? (Journal of Chromatography A, Volume 1228, 9 March 2012, Pages 72–88)
    Superficially Porous Particles: Perspectives, Practices, and Trends (LCGC North America, Volume 32, 2014, Issue 6, pg 420–433)

    For more information contact our sales team at BGB Analytik or visit our shop.

    Raptor_Columns_Fan_white_sm