Fortis SpeedCore® C18 PFP – New Fused Core Technology

Speedcore® C18-PFP increases selectivity over alkyl chain stationary phase particles. Leading to a combination of high efficiency, resolution and sensitivity.
  • Orthogonal selectivity
  • Improve resolution even at high speed
  • Provide high efficiency
  • Excellent method development option
SpeedCore C18-PFP structure
SpeedCore® C18-PFP features a mixture of C18 alkyl chain ligands and Penta­Fluoro­Phenyl (PFP) ligands. This provides multiple mechanisms of interaction between statio­nary phase and analytes, allowing for unique selectivity of closely related species and meta­bolites. No complex mobile phase additives are necessary, therefore simplifying LC method development.
  • π-π (high selectivity)
  • Steric selectivity
  • Hydrophobicity (highly stable)
Orthogonal Selectivity – Substituted Benzenes
Orthogonal Selectivity

Fortis SpeedCore C18-PFP 80Å Series can be obtained here:
Fortis SpeedCore C18-PFP 80Å – 2.6µm
Fortis SpeedCore C18-PFP 80Å – 5µm

New Agilent InfinityLab Poroshell 120 1.9 μm columns

New Agilent InfinityLab Poroshell 120 1.9 μm columns provide a unique combination of high efficiency, manageable pressure, and long lifetime.

  • Ultra-fast separations increase productivity and decrease your cost per sample
  • Increase resolution and accuracy and reduce re-work by combining manageable pressure with longer, high efficiency InfinityLab Poroshell 120 1.9 μm colums
  • Rugged performance: InfinityLag Poroshell 120 1.9 μm columns remain stable for 5000 injections under high-pressure UHPLC conditions.
Poroshell 120

InfinityLab Poroshell 120 columns are based on superficially porous particle technology, which features a solid silica core and a porous outer layer. Compared to traditional totally porous particles of the same (or similar) size, InfinityLab Poroshell particles deliver higher chromatographic efficiencies and enable fast, high-resolution separations.

Solid Core Porous Layer Particle size Pressure Limit
1.2 μm 0.35 μm 1.9 μm 1300 bar

Use long-life and robust InfinityLab Poroshell 120 1.9 μm columns and chose the most suitable chemistry for your method:

Best use Aligned Chemistry Column family
Best all around EC-C18 Poroshell 120 Eclipse EC-C18
EC-C8 Poroshell 120 Eclipse EC-C8
Phenyl-Hexyl Poroshell 120 Phenyl-Hexyl
Best for high-pH mobile phases HPH-C18 Poroshell 120 HPH-C18
Best for alternative selectivity PFP
(Pentafluorophenyl)
Poroshell 120 PFP
Best for more polar compounds HILIC Poroshell 120 HILIC

Application Note – SpeedCore Method Transfer Document by Fortis Technologies

fortisHPLC

Fortis® Technologies Ltd. supplies UHPLC and HPLC columns to the pharmaceutical, environmental and foodstuffs industries. Their goal is to supply innovative solutions to the separation and purification industries.

In their new application note – Transfer of HPLC methods to SpeedCore particles – they outline how to transfer an old slow HPLC method to core-shell particles in order to provide a much faster method. Learn how to use 3 simple equations to change parameters to do this.

Method development kits from Fortis Technologies Ltd. can be obtained here:
Reversed Phase Selectivity Kit (C18 & Diphenyl)
Polar Selectivity Kit (H2o & DIOL)
SpeedCore Selectivity Kit (C18 & RP18-Amide)
SpeedCore Reversed Phase Kit (C18 & Diphenyl)

Heliflex™ and Econocap™ GC Columns still available

helifax

MEGA is the exclusive authorized licensee of the Heliflex™ and Econo-Cap™ GC columns and will continue to produce* the “ATTM -” and “ECTM -” GC columns (for example ATTM-624+ or ECTM-WAX+) in order to supply you with HeliflexTM and Econo-CapTM GC columns fully equivalent to those you’ve always used until now.
The GC columns are available at BGB Analytik. We will support you in your product-specific concerns and questions. Please contact us for more information or to place an order.


*:under W. R. Grace & Co.-Conn. (GRACE) and Alltech Associates, Inc. exclusive License
GRACE® is a trademark, registered in the United States and/or other countries, of W. R. Grace & Co.-Conn. ECONO-CAP™, HELIFLEX™, AT™ and EC™ are trademarks of Alltech Associates, Inc. MEGA® (Stylized) is a trademark, registered in the United States and/or other countries, of MEGA Capillary Columns Laboratory di Galli Stefano & C. s.n.c.

BGB HPLC Safety Products

Header_Safety_Products
The new BGB HPLC Safety Products offer maximum protection and operability for safe disposal of fluid waste and extraction systems of fluids without evaporation of hazardous substances. BGB HPLC Safety Products are compatible with the S.C.A.T.® product line, perfect in handling and easy to use.
Safety-Waste-Filter
Waste-Caps
Safety Air Inlet Valve
Safety-Caps
Safety-Funnel
Safety Accessories & Adapters
BGB offers 20% on BGB HPLC Safety Products valid until 31.12.2016. To benefit use promocode BG1611.
This promotion cannot be cumulated with other reductions or special tariffs.

T1 deactivated SGE Inlet Liners

Developed specifically for EPA Method 8270 – for determination of semi-volatile organic compounds in extracts prepared from many types of solid waste, soils, water samples, and air sampling media -Trajan’s TI deactivated liners are unique and application specific, extensively tested and optimized for semi-volatiles analysis.

SGE TI deactivated liner

Several compounds in Method 8270 are susceptible to excessive degradation in the GC flow path and are potentially difficult to analyse if the inlet liner is not properly deactivated. Trajan’s TI deactivated liners are tested using a mix containing low levels (2ng on column) of problematic compounds:
N-nitrosodimethylamine, aniline, 2,4-dinitrophenol, 4-nitrophenol, 2-methyl-4,6-dinitrophenol, 4-aminobiphenol, pentachlorophenol, benzidine, benzo(b)fluoranthene, benzo(k)fluoranthene, and 3,3′-dichlorobezidine

More information about Trajan’s TI deactivated liners is available here.

Deactivation of SGE TI Inlet Liners for EPA 8270 semi-volatiles analysis is certified using 2,4-dinitrophenol and pentachlorophenol to ensure response factors above EPA method requirements.

SGE TI Inlet Liners are now available for Agilent and Thermo 1300 series instruments.

Part Number SGE-09262019 – Agilent Inlet Liners Tapered with Quartz Wool pre-fitted o-ring and TI Deactivation 4 mm ID, Length 78.5 mm PK5
Part Number SGE-0926201901 – Agilent Inlet Liner Tapered with Quartz Wool pre-fitted o-ring and TI Deactivation 4 mm ID, Length 78.5 mm PK1

Invitation to ILMAC in Basel

From the 20th – 23rd of September 2016, Basel will become the most important meeting place for the pharmaceutical and chemistry market in Switzerland. At the ILMAC, the convention for industry and laboratory technology, suppliers, manufacturers and buyers gather from the fields of laboratory needs, analytics, specialty chemistry, information technology, processing systems, environmental technology and quality control.

With our motto – Chromatography is our Business – you can have a conversation with our experts and learn more about proven or new products and solutions for your needs in the field of chromotography. For a brief online overview of us, see the ILMAC index of exhibitors and products.

Stop by and see us at Booth B221 in Hall 1.1 and, with a little luck, you could win an Apple iPad Air2 64GB or an Apple iPad Mini2 32GB.

To receive a free entry ticket, register at the ILMAC Online Shop at www.ilmac.ch/ticket using the following Priority Code: bgbanalytik-ilmac16

We look forward to seeing you!
The BGB Analytik Team

Agilent BioHPLC Seminar

Agilent AdvanceBio columns are designed to enhance the accuracy and speed of your biomolecule characterization, including monoclonal antibodies (mAbs), other proteins, peptides and synthetic oligonucleotides.

This seminar aims at giving the audience a brief insight in the advantages and use of Advance BioHPLC Performance products.

SPEAKERS

Mrs Katrien Sabbe, PhD in Chemistry. More than 15 years experience in chromatography in differents companies as VWR, Varian and now Agilent Technologies. Product Specialist columns and supplies for Benelux area.

Mr Francesco Spadola, PhD in Chemistry. Product Specialist columns and supplies for the complete south of Europe. Many years experience in both liquid chromatography (LC) and sample preparation.

The presentations are in French
Slides, questions and discussion in both French and English.
Entrance is free of charge

For registration please contact Cyril Poulard, BGB Analytik SA, Geneva.

AGENDA
Download as pdf

09:00 – 09:30 Arrival & registration – coffee
09:30 – 09:40 Welcome words
09:40 – 10:20 Characterizing MAbs: Typical analytical workflows and Agilent portfolio overview
10:20 – 11:10 Reversed Phase BioHPLC columns for Protein Identification and Impurity Profiling
11:10 – 11:30 Coffee break
11:30 – 12:15 Optimizing Quantification of mAb and ADC Aggregates with Agilent AdvanceBio SEC columns
12:15 – 13:45 Lunch
13:45 – 14:30 Overview of Agilent Glycan Mapping Solution
14:30 – 14:50 Coffee break
14:50 – 15:35 Ion Exchange Chromatography for charge variants analysis
15:35 – 15:45 Conclusion and closing comments

GoogleMaps View Location on Google Maps.

Using Alternative Carrier Gases with Accelerated ASTM D2887 Simulated Distillation Analysis

By Katarina Oden, Barry Burger, and Amanda Rigdon.
PCAR2320-UNV_header

ASTM Method D2887 now allows for alternate carrier gases, so hydrogen or nitrogen can replace helium carrier gas for simulated distillation. Here is shown that with an MXT®-1HT SimDist column and Restek’s EZGC® online method translator existing methods using helium can be easily converted to either hydrogen or nitrogen carrier gas. Because retention times are preserved with proper method translation, there are minimal changes to peak identification tables, which significantly simplifies method validation.

Read the article provided by Restek